[PATCH 02/15] tools/lib/traceevent: Add mono clocks to be parsed in seconds

From: Steven Rostedt
Date: Mon Apr 01 2019 - 12:43:59 EST


From: "Steven Rostedt (VMware)" <rostedt@xxxxxxxxxxx>

The mono clocks can display in seconds instead of whole numbers:

trace-cmd-521 [001] 99176715281005: sched_waking: comm=kworker/u16:2 pid=32118 prio=120 target_cpu=002
trace-cmd-521 [001] 99176715286349: sched_wake_idle_without_ipi: cpu=2
trace-cmd-521 [001] 99176715288047: sched_wakeup: kworker/u16:2:32118 [120] success=1 CPU:002
trace-cmd-521 [001] 99176715290022: sched_waking: comm=trace-cmd pid=523 prio=120 target_cpu=000
trace-cmd-521 [001] 99176715292332: sched_wake_idle_without_ipi: cpu=0
trace-cmd-521 [001] 99176715292855: sched_wakeup: trace-cmd:523 [120] success=1 CPU:000
trace-cmd-521 [001] 99176715300697: sched_stat_runtime: comm=trace-cmd pid=521 runtime=80233 [ns] vruntime=66705540554 [ns

Break it up in seconds:

trace-cmd-521 [001] 99176.715281: sched_waking: comm=kworker/u16:2 pid=32118 prio=120 target_cpu=002
trace-cmd-521 [001] 99176.715286: sched_wake_idle_without_ipi: cpu=2
trace-cmd-521 [001] 99176.715288: sched_wakeup: kworker/u16:2:32118 [120] success=1 CPU:002
trace-cmd-521 [001] 99176.715290: sched_waking: comm=trace-cmd pid=523 prio=120 target_cpu=000
trace-cmd-521 [001] 99176.715292: sched_wake_idle_without_ipi: cpu=0
trace-cmd-521 [001] 99176.715293: sched_wakeup: trace-cmd:523 [120] success=1 CPU:000
trace-cmd-521 [001] 99176.715301: sched_stat_runtime: comm=trace-cmd pid=521 runtime=80233 [ns] vruntime=66705540554 [ns]

Signed-off-by: Steven Rostedt (VMware) <rostedt@xxxxxxxxxxx>
---
tools/lib/traceevent/event-parse.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/tools/lib/traceevent/event-parse.c b/tools/lib/traceevent/event-parse.c
index 2ebb257ce7ba..666e23ded6ed 100644
--- a/tools/lib/traceevent/event-parse.c
+++ b/tools/lib/traceevent/event-parse.c
@@ -5445,7 +5445,8 @@ static bool is_timestamp_in_us(char *trace_clock, bool use_trace_clock)
return true;

if (!strcmp(trace_clock, "local") || !strcmp(trace_clock, "global")
- || !strcmp(trace_clock, "uptime") || !strcmp(trace_clock, "perf"))
+ || !strcmp(trace_clock, "uptime") || !strcmp(trace_clock, "perf")
+ || !strncmp(trace_clock, "mono", 4))
return true;

/* trace_clock is setting in tsc or counter mode */
--
2.20.1